Product Features
- High performance, low noise scroll compressors to match the required total load.
- Resiliently factory-mounted on rubber grommets for vibration isolation
- Refrigeration circuit includes both high and low pressure safety switches
- Unit is factory charged with environmentally friendly Low GWP R32 refrigerant
- Two-stage scroll compressor for partial load applications
- Compressor location outside the condenser section to avoid air bypass
- The Direct-Drive airfoil single width, single inlet (SWSI) Class II construction supply fan with aluminum fan blades provides efficient and quiet operation at wide ranging static pressure and air flow requirements
- Fan wheel is continuously welded to the hub plate and end rim for long lasting reliable operation
- Direct-drive ECM motor removes the need for belts, sheaves, or bearings and its permanently lubricated motors provides low maintenance cost
- Each fan assembly is dynamically trim balanced at the factory before shipment for quick start-up and efficient operation
- Motor equipped with thermal overload to provide protection and lasting operation
- The indoor coil section is installed in a draw through configuration to provide better dehumidification. These coils are constructed with seamless copper tubes, mechanically bonded into aluminum plate-type fins with full drawn collars to completely cover the tubes for high operating efficiencies.
- Coils are factory pressure tested to ensure pressure and leak integrity.
- Copper tube / aluminum fin coils on evaporator
- All units use large face area outdoor coils
- Evaporator coil, condenser coil, compressors and refrigerant circuit are designed for heat pump operation.
- The reversing valve switches position depending on cooling or heating demand
- The outdoor coil includes a thermal expansion valve to control the refrigerant flow during heat pump operation.
- Hybrid heating option is provided for auxiliary heating.
- Microchannel heat exchanger technology on all condenser coils for improved performance and reduced refrigerant load.
- Units are factory-wired with color-coded wires and complete 24-volt Electromechanical controls package.
- Units include single-point power entry as standard.
- Terminal strips are provided as standard for easy installation and low voltage power wiring
- Unit provides a draw-through filter section as standard for better air quality and long lasting component maintenance. Filters installed on the units are standard off the shelf sizes for easy replacement.